CaltechTHESIS
  A Caltech Library Service

Computational Design of Wearable Chemical Sensors for Personalized Healthcare

Citation

Mukasa, Daniel (2025) Computational Design of Wearable Chemical Sensors for Personalized Healthcare. Dissertation (Ph.D.), California Institute of Technology. doi:10.7907/r46k-sw73. https://resolver.caltech.edu/CaltechTHESIS:06292024-045659387

Abstract

Wearable sweat sensors have the potential to revolutionize precision medicine as they can non-invasively collect molecular information closely associated with an individual’s health status. However, the majority of clinically relevant biomarkers cannot be continuously detected in situ using existing wearable approaches. Molecularly imprinted polymers (MIPs) are a promising candidate to address this challenge but haven’t yet gained widespread use due to their complex design and optimization process yielding variable selectivity. Despite their promise, MIPs have historically been known to be exceedingly difficult to optimize. Changes in the monomer/monomers used, polymerization solvent, and crosslinking agent have been shown to change the performance of MIP sensors significantly. This is particularly a concern in sweat-based sensors where the concentration of analytes is very low and chemical diversity is very high as a drop of sweat can contain vitamins, hormones, and amino acids. Consequentially, any sweat based sensor must exhibit high sensitivity (ability to detect low analyte concentrations) and selectivity (ability to distinguish one analyte from another). Computational methods have been introduced to design MIP sensitivity alone, however these prior methods do not cover all aspects essential for using a sensor in a wearable device such as selectivity optimization, detection of non-electroactive analytes, and scalable manufacturing. Here, we introduce a full computational method that allows for high throughput materials discovery for wearable devices. We will describe how to design novel sensing materials with QuantumDock, an automated computational framework for universal MIP development toward wearable applications. Then we delve into further technical details on signal transduction and scalable manufacturing approaches for these wearable devices. We present a number of novel devices designed with these computational methods including a wearable non-invasive phenylalanine monitoring system (the first of its kind), a wearable nutritional tracker ‘Nutritrek’ capable of monitoring a range of metabolic disorders, and an implantable pharmaceutical drug monitoring system for cancer patients.

Item Type:Thesis (Dissertation (Ph.D.))
Subject Keywords:Computational Design, Wearable Devices, Biotech
Degree Grantor:California Institute of Technology
Division:Engineering and Applied Science
Major Option:Materials Science
Thesis Availability:Public (worldwide access)
Research Advisor(s):
  • Gao, Wei
Thesis Committee:
  • Goddard, William A., III (chair)
  • Schwab, Keith C.
  • Kornfield, Julia A.
  • Gao, Wei
Defense Date:12 July 2024
Record Number:CaltechTHESIS:06292024-045659387
Persistent URL:https://resolver.caltech.edu/CaltechTHESIS:06292024-045659387
DOI:10.7907/r46k-sw73
ORCID:
AuthorORCID
Mukasa, Daniel0000-0001-8379-3648
Default Usage Policy:No commercial reproduction, distribution, display or performance rights in this work are provided.
ID Code:16530
Collection:CaltechTHESIS
Deposited By: Daniel Mukasa
Deposited On:22 Oct 2024 18:37
Last Modified:22 Oct 2024 18:37

Thesis Files

[img] PDF (Redacted thesis - ch. 6-7 omitted) - Final Version
See Usage Policy.

6MB
[img] Archive (ZIP) (Contains raw images of each figure in the thesis) - Supplemental Material
See Usage Policy.

30MB

Repository Staff Only: item control page