Citation
Baller, Howard (1946) Losses in Cavity Resonators. Dissertation (Ph.D.), California Institute of Technology. doi:10.7907/nmmx-dk82. https://resolver.caltech.edu/CaltechTHESIS:05032025-230624898
Abstract
The problem investigated was the measurement of the Q, or figure of merit, of a resonant cavity and observation of the variation in Q with changes in the size and shape of the coupling holes. A method of measurement was developed using a spectrum analyzer as a detector and a signal with a known spectrum to calibrate the analyzer for frequency changes. The results indicate that the Q is lowered if the size of the coupling windows is increased. There are two contributions to the losses which may be considered separately; the losses on the inner walls of the resonator, and the losses due to energy radiated out of the coupling hole.
Item Type: | Thesis (Dissertation (Ph.D.)) |
---|---|
Subject Keywords: | Electrical engineering |
Degree Grantor: | California Institute of Technology |
Division: | Engineering and Applied Science |
Major Option: | Electrical Engineering |
Thesis Availability: | Public (worldwide access) |
Research Advisor(s): |
|
Thesis Committee: |
|
Defense Date: | 1946 |
Record Number: | CaltechTHESIS:05032025-230624898 |
Persistent URL: | https://resolver.caltech.edu/CaltechTHESIS:05032025-230624898 |
DOI: | 10.7907/nmmx-dk82 |
Default Usage Policy: | No commercial reproduction, distribution, display or performance rights in this work are provided. |